Digital Analysis (QAM View OPT4): Equalizer Mode
175
9
A primary function of this mode is to help the user maintain low levels of
equalizer stress by locating excessive equalization at specific QAM
demodulator digital filter coefficients that require correction.
Each vertical bar on the graph represents an equalizer filter coefficient. The
highest bar represents the test point location, and the descending line to the
right of this bar is the high mask. Vertical bars approaching or exceeding
this line will register a high stress reading on the display. The medium and
low masks are not shown on the graph, but each filter coefficient registers
readings with these masks in the same manner.
Basic Operation
To activate EQUALIZER Mode, press the green Function key and then
press the Hum Measurement Mode key.
EQUALIZER Main Screen
From the EQUALIZER Main Screen (Fig. 9-20) you can
use the right or left diamond keys to place the marker over the desired
measurement coefficient
move to the LEVEL Submenu to edit the Reference Level or Scale
Parameter of the graph
select the In-Channel Frequency Response Screen
select the In-Channel Group Delay Screen.
Use the left and right diamond keys to place the vertical marker over the filter
coefficient to be measured.