Automatic Test: Auto Test Results
192
10
• The Info soft key displays the test location characteristics for the
selected file. This is the information that was logged when you
configured the test. The items presented depend on the location type
that you selected.
• When you have selected an Auto Test file, you are presented with a list
of intervals that are contained within the file. The list includes the interval
number, date, time, and temperature when the interval was recorded,
and the Pass/Fail results.
• An "X" in the Pass/Fail column indicates an overall failure of the
measurements taken during that interval. A check mark indicates that
all measurements were within the specified limits.
NOTE: Immediate Auto Test sequence runs consist of one
interval only.
• A 24-hour report is available to assist you in documenting proof-of-
performance compliance measurements. Pressing the 24hr Report soft
key causes the instrument to automatically format and print the
highlighted interval plus the next three intervals. The following is an
example of a 24-Hour Test Report:
-------------------------------------------------------------------
Acterna 24 HOUR TEST REPORT
Model: SDA-5000 Serial No: 1234567 Cal Date: 01/07/00
-------------------------------------------------------------------
Operator: JOHN File: T1
-------------------------------------------------------------------
Location Name: 1028_ELM_ST
Location Type: Trunk
Test Point Type: Forward Trunk In
Test Point Compensation: +0.0 dB
-------------------------------------------------------------------
Area: 00A7
Amp ID: 12-275Z
Power Config: In
Feeder Maker Config: 1
Trunk Termination: No
Voltage Setting: Low
Reverse Pad: +0.0 dB Reverse Equalizer: +0.0 dB
Forward Pad: +0.0 dB Forward Equalizer: +0.0 dB
-------------------------------------------------------------------
AC Voltage: 110 V DC Voltage (reg): 14.8 V (unreg): 20.9 V
-------------------------------------------------------------------