Field Sweeping with the SDA-5000: Test Point Compensation
63
4
As an example, consider the amplifier shown in Fig. 4-3:
Fig. 4-3 Test Point Compensation Values
Measured at the test points available at the output of the amplifier, the
forward test point loss is 20dB. If youre balancing constant inputs to
the hybrid, the reverse test point loss is 20dB for the test point, plus
1.0dB for a diplexer, plus 3.5dB for a splitter, plus the pad value at the
input to the reverse amplifier (for example, assume 3dB). This would
be entered as 20dB of test point loss and 7.5dB of internal losses.
This value would be entered in the top data box in the display. In this
configuration, a splitter would be required to combine the two output
ports of the SDA-5000. This would be entered as 3.5dB of loss in the
external entry for both forward and reverse test point compensation.
5. The telemetry and sweep generation and injection levels are
displayed in the TESTPOINT INFO screen (see Fig. 4-4). The
generated levels are calculated based on the desired system levels
set at the main SWEEP configuration menu (see Sweep
Configuration on page 64), and the test point losses entered here.
The telemetry level is calculated precisely for a specific frequency and
level. This value can be used with the headend display to perform
absolute level alignment, so it is calculated to 0.1dB resolution.