SDA-5500/SDA-5510 Sweep Configuration: Forward Sweep Configuration (SDA-5500)
272
14
Fig. 14-4 The SWEEP TRANSCEIVER Main Menu
Use the up and down arrow keys or the numeric keypad to enter the
telemetry frequency.
Do not place the telemetry signal too close to the diplex filter cut-off
frequency in that roll-off may attenuate the telemetry signal to the degree
that communication fails. This same caution applies to placing the signal in
the high end roll-off region. Take care not to place the telemetry too far into
the edges of the forward path band. Inconsistent operation may result if the
telemetry channel is too close to the band edge. In order to sweep with an
SDA-5500, an SDA field unit must have matching telemetry frequency
values.
Forward Telemetry Level
This is the level of the carrier that the SDA-5500 uses to transmit telemetry
data. Use the Edit Box to set the telemetry level to an appropriate value.
When adjusting the telemetry level, take into consideration the following
losses: system, summing network, test point, and amplifier desired input.
Use the up and down arrow keys or the numeric keypad to enter the
telemetry level (20-50 dBmV).
Forward Sweep Insertion Level
This is the level at which the SDA-5500 inserts (transmits) sweep points. All
sweep points are inserted at the same level. Use the Edit Box to set the
sweep insertion level to an appropriate value (This will typically be at
maximum (+50 dBmV) to over come test point loss.).